Config Tab

The Config tab provides access to all major LabOne settings and is available on all MFLI instruments.

Features

  • define instrument connection parameters
  • browser session control
  • define UI appearance (grids, theme, etc.)
  • store and load instrument settings and UI settings
  • configure data recording

Description

The Config tab serves as a control panel for all general LabOne settings and is opened by default on start-up. Whenever the tab is closed or an additional one of the same type is needed, clicking the following icon will open a new instance of the tab.

Table 1: App icon and short description
Control/Tool Option/Range Description
Config Provides access to software configuration.

The Config tab (see Figure 1) is divided into four sections to control connections, sessions, settings, user interface appearance and data recording.

Figure 1: LabOne UI: Config tab

The Connection section provides information about connection and server versions. Access from remote locations can be restricted with the connectivity setting.

The Session section provides the session number which is also displayed in the status bar. Clicking on Session Dialog opens the session dialog window (same as start up screen) that allows one to load different settings files as well as to connect to other instruments.

The Settings section allows one to load and save instrument and UI settings. The saved settings are later available in the session dialog.

The User Preferences section contains the settings that are continuously stored and automatically reloaded the next time an MFLI instrument is used from the same computer account.

For low ambient light conditions the use of the dark display theme is recommended (see Figure 2).

Figure 2: LabOne UI: Config tab - dark theme

The Record Data section contains all settings necessary to obtain hard copies of measurement data. The tree structure (see Tree Selector section) provides access to a large number of signals and instrument settings. Use the View Filter in order to reduce the tree structure to the most commonly used nodes such as the demodulator sample nodes. Whenever the Record button is enabled, all selected nodes get saved continuously in MATLAB, comma-separated value (CSV), or other supported file formats. For each selected node at least one file gets generated, but the data may be distributed over several files during long recordings.

The files are normally saved to the internal storage of the MFLI or on a mass storage device connected to one of the instrument’s USB ports. In order to save data directly on the host computer, please install and run the LabOne Web Server on the host computer as described in Running LabOne on a Separate PC.

See Saving and Loading Data for more information on data saving. The quickest way to inspect the files after recording is to use the File Manager tab described in File Manager Tab. Apart from the numerical data and settings, the files contain timestamps. These integer numbers encode the measurement time in units of the instrument clock period 1/(60 MHz). The timestamps are universal within one instrument and can be used to align the data from different files.

Functional Elements

Table 2: Config tab
Control/Tool Option/Range Description
About Get information about LabOne software.
Web Server Version and Revision string Web Server version and revision number
Host default is localhost: 127.0.0.1 IP-Address of the LabOne Web Server
Port 4 digit integer LabOne Web Server TCP/IP port
Data Server Version and Revision string Data Server version and revision number
Host default is localhost: 127.0.0.1 IP-Address of the LabOne Data Server
Port default is 8004 TCP/IP port used to connect to the LabOne Data Server.
Connect/Disconnect Connect/disconnect the LabOne Data Server of the currently selected device. If a LabOne Data Server is connected only devices that are visible to that specific server are shown in the device list.
Status grey/green Indicates whether the LabOne User Interface is connected to the selected LabOne data server. Grey: no connection. Green: connected. Red: error while connecting.
Connectivity From Everywhere Forbid/Allow to connect to this Data Server from other computers.
Localhost Only
File Upload drop area Drag and drop files in this box to upload files. Clicking on the box opens a file dialog for file upload.

Supported files: Settings (*.xml), software update (LabOne*.tar). Uploading software updates will automatically trigger the update process if the file is valid and has a different revision than the currently installed software.
Session Id integer number Session identifier. A session is a connection between a client and LabOne Data Server.
Session Manager Open the session manager dialog. This allows for device or session change. The current session can be continued by pressing cancel.
File Name selection of available file names Save/load the device and user interface settings to/from the selected file on the internal flash drive. The setting files can be downloaded/uploaded using the Files tab.
Include Enable Save/Load of particular settings.
No Include Settings Please enable settings type to be included during Save/Load.
Include Device Enable Save/Load of Device settings.
Include UI Enable Save/Load of User Interface settings.
Include UI and Device Enable Save/Load of User Interface and Device settings.
Include Preferences Enable loading of User Preferences from settings file.
Include UI, Device and Preferences Enable Save/Load of User Interface, Device and User Preferences.
Save Save the user interface and device setting to a file.
Load Load the user interface and device setting from a file.
Load From USB Load public SSH keys from the USB mass storage connected to the device. Uploading of SSH keys enables SSH access to the device.
Delete All Delete all public SSH keys on the device.
Time Zone Timezone offset from UTC (Coordinated Universal Time). Select the time zone in which the device is used. Settings, data and log files receive timestamps from this time zone. Requires a power cycle for changes to become effective.
Display Theme Dark Choose theme of the user interface.
Light
Plot Print Theme Dark Choose theme for printing SVG plots.
Light
Plot Grid None Select active grid setting for all SVG plots.
Dashed
Solid
Plot Rendering Select rendering hint about what tradeoffs to make as the browser renders SVG plots. The setting has impact on rendering speed and plot display for both displayed and saved plots.
Auto Indicates that the browser shall make appropriate tradeoffs to balance speed, crisp edges and geometric precision, but with geometric precision given more importance than speed and crisp edges.
Optimize Speed The browser shall emphasize rendering speed over geometric precision and crisp edges. This option will sometimes cause the browser to turn off shape anti-aliasing.
Crisp Edges Indicates that the browser shall attempt to emphasize the contrast between clean edges of artwork over rendering speed and geometric precision. To achieve crisp edges, the user agent might turn off anti-aliasing for all lines and curves or possibly just for straight lines which are close to vertical or horizontal.
Geometric Precision Indicates that the browser shall emphasize geometric precision over speed and crisp edges.
Resampling Method Select the resampling interpolation method. Resampling corrects for sample misalignment in subsequent scope shots. This is important when using reduced sample rates with a time resolution below that of the trigger.
Linear Linear interpolation
PCHIP Piecewise Cubic Hermite Interpolating Polynomial
Show Shortcuts ON / OFF Displays a list of keyboard and mouse wheel shortcuts for manipulating plots.
Dynamic Tabs ON / OFF If enabled, sections inside the application tabs are collapsed automatically depending on the window width.
Graphical Mode Collapsed Select the display mode for the graphical elements. Auto format will select the format which fits best the current window width.
Auto
Expanded
Log Format .NET Choose the command log format. See status bar and [User]\Documents\Zurich Instruments\LabOne\WebServer\Log
MATLAB
Python
CSV Delimiter Tab Select which delimiter to insert for CSV files.
Comma
Semicolon
CSV Locale System locale. Use the symbols set in the language and region settings of the computer Select the locale used for defining the decimal point and digit grouping symbols in numeric values in CSV files. The default locale uses dot for the decimal point and no digit grouping, e.g. 1005.07. The system locale uses the symbols set in the language and region settings of the computer.
Default locale. Dot for the decimal point and no digit grouping, e.g. 1005.07
HDF5 Saving Multiple files. Each measurement goes in a separate file For HDF5 file format only: Select whether each measurement should be stored in a separate file, or whether all measurements should be saved in a single file.
Single file. All measurements go in one file
Auto Start ON / OFF Skip session manager dialog at start-up if selected device is available.

In case of an error or disconnected device the session manager will be reactivated.
Update Reminder ON / OFF Display a reminder on start-up if the LabOne software wasn't updated in 180 days.
Update Check ON / OFF Periodically check for new LabOne software over the internet.
Drive Select the drive for data saving.
MF Flash Drive Internal flash mass storage device of the MFLI/MFIA.
USB 1/2 Mass storage device connected on USB.
Format HDF5 File format of recorded and saved data.
MATLAB
CSV
Open Folder Open recorded data in the system File Explorer.
Folder path indicating file location Folder containing the recorded data.
Save Interval Time in seconds Time between saves to disk. A shorter interval means less system memory consumption, but for certain file formats (e.g. MATLAB) many small files on disk. A longer interval means more system memory consumption, but for certain file formats (e.g. MATLAB) fewer, larger files on disk.
Queue integer number Number of data chunks not yet written to disk.
Size integer number Accumulated size of saved data in the current session.
Record ON / OFF Start and stop saving data to disk as defined in the selection filter. Length of the files is determined by the Window Length setting in the Plotter tab.
Writing grey/green Indicates whether data is currently written to disk.
Display filter or regular expression Display specific tree branches using one of the preset view filters or a custom regular expression.
Tree ON / OFF Click on a tree node to activate it.
All Select all tree elements.
None Deselect all tree elements.

For more information on the tree functionality in the Record Data section, please see Tree Selector.