CZ Gate Calibration with Tunable Couplers

Prerequisites

This guide assumes you have a configured DeviceSetup as well as Qubit objects with assigned parameters. Before you can calibrate a CZ gate, you need to have tuned up the single-qubit drive and readout of both qubits, and to have parked the tunable coupler at a bias that minimizes the residual ZZ coupling (see the ZZ coupling guide). Please see our tutorials if you need to create your setup and qubits for the first time.

You can run this notebook on real hardware in the lab. However, if you don't have the hardware at your disposal, you can also run the notebook "as is" using an emulated session (see below).

If you are just getting started with the LabOne Q Applications Library, please don't hesitate to reach out to us at info@zhinst.com.

Background

In this guide, you will learn how to calibrate a CZ gate between a pair of TunableTransmonQubits mediated by a TunableCoupler.

The gate mechanism

The CZ gate calibrated here is a dynamical flux gate: it realizes a conditional phase of \(\pi\) on the \(|11\rangle\) state by tuning the \(|11\rangle\) state into resonance with the \(|20\rangle\) state for a well-defined duration. During this time, the \(|11\rangle\) state makes a full round-trip in the two-state manifold (Bloch sphere) spanned by \(|11\rangle\) and \(|20\rangle\), thereby acquiring a geometric phase of \(\pi\) [1, 2]. Because the round-trip must be complete — any residual population left in \(|20\rangle\) at the end of the pulse is leakage out of the computational subspace — both the amplitude (which sets the detuning from the \(|11\rangle \leftrightarrow |20\rangle\) resonance) and the duration of the flux pulse have to be calibrated precisely.

In the implementation used here, the interaction is activated parametrically [3]: a flux pulse modulated at the parametric-drive frequency (the modulated_flux pulse) is played on the flux line of the qubit with the higher ge frequency, while a simultaneous baseband pulse on the coupler flux line brings the coupling strength up for the duration of the gate. The gate ends with single-qubit phase corrections (virtual-Z rotations) on both qubits.

The cz quantum operation of TunableCouplerOperations implements this sequence. The parameters of the gate are stored on a QPU topology edge tagged "cz", whose parameters are an instance of CzParameters:

  • control_pulse: the fast-flux pulse played on the qubit flux line,
  • coupler_pulse: the fast-flux pulse played on the coupler flux line,
  • control_angle and target_angle: the single-qubit phase corrections.

Note that the same cz operation also supports a coupler-driven flavor, in which the modulated flux pulse is played on the coupler itself and no qubit flux pulse is used. That flavor is selected by leaving control_pulse set to None (the default), and its calibration is covered by the para_cz_* workflows in laboneq_applications.contrib.experiments.two_qubit. This guide covers the qubit-driven flavor, where control_pulse is set.

The calibration procedure

The calibration proceeds in three steps, each one an experiment Workflow from laboneq_applications.contrib.experiments:

  1. Chevron (chevron): sweep the duration and the amplitude of the fast-flux pulses while both qubits are prepared in \(|1\rangle\). The characteristic chevron pattern of the \(|11\rangle \leftrightarrow |20\rangle\) avoided crossing reveals the operating point \((a_{CZ}, l_{CZ})\) of the gate.
  2. JAZZ (jazz): a Ramsey-type sequence with two CZ gates and an echo pulse, used to fine-tune the conditional-phase accumulation of the gate to the target value of \(\pi\).
  3. Phase correction (phase_correction): Ramsey-type measurements on the control and target qubits that determine the single-qubit phase corrections control_angle and target_angle.

Imports

You'll start by importing laboneq.simple.

from laboneq.simple import *

Define your experimental setup

Let's define our experimental setup. We will need:

Here, we will show explicitly how to build these objects, since the "cz" topology edges and their CzParameters are the essential new ingredient compared to the single-qubit guides.

number_of_qubits = 2

DeviceSetup

This guide requires a setup that can drive and readout two tunable transmon qubits, and that provides flux lines for the qubits and the tunable coupler. Here, we will use an SHFQC+ with 6 signal generation channels, an HDAWG with 8 channels, and a PQSC.

If you have used LabOne Q before and already have a DeviceSetup for your setup, you can reuse that.

If you do not have a DeviceSetup, you can create one using the code below. Just change the device numbers to the ones in your rack and adjust any other input parameters as needed.

from laboneq.contrib.example_helpers.generate_device_setup import generate_device_setup

setup = generate_device_setup(
    number_qubits=number_of_qubits,
    pqsc=[{"serial": "DEV10001"}],
    shfqc=[
        {
            "serial": "DEV12001",
            "number_of_channels": 6,
            "readout_multiplex": 6,
            "options": "SHFQC/PLUS/QC6CH/RTR",
        }
    ],
    hdawg=[
        {"serial": "DEV8800", "number_of_channels": 8, "options": "HDAWG8/CNT/ME/PC"}
    ],
    include_flux_lines=True,
    server_host="localhost",
)

Qubits

We will generate 2 TunableTransmonQubits from the logical signal groups in our DeviceSetup, and configure their parameters to reflect the properties of the qubits on your QPU.

from laboneq_applications.qpu_types.tunable_transmon import TunableTransmonQubit

qubits = TunableTransmonQubit.from_device_setup(setup)

for q in qubits:
    q.parameters.ge_drive_pulse["sigma"] = 0.25
    q.parameters.readout_amplitude = 0.5
    q.parameters.reset_delay_length = 1e-6
    q.parameters.readout_range_out = -25
    q.parameters.readout_lo_frequency = 7.4e9

qubits[0].parameters.drive_lo_frequency = 6.4e9
qubits[0].parameters.resonance_frequency_ge = 6.3e9
qubits[0].parameters.resonance_frequency_ef = 6.0e9
qubits[0].parameters.readout_resonator_frequency = 7.0e9

qubits[1].parameters.drive_lo_frequency = 6.4e9
qubits[1].parameters.resonance_frequency_ge = 6.5e9
qubits[1].parameters.resonance_frequency_ef = 6.3e9
qubits[1].parameters.readout_resonator_frequency = 7.3e9

Tunable Coupler

Let's now add the tunable coupler to our setup. We name the coupler after the qubits it connects and manually add its flux line to the setup. The connectivity will be formalized later in the QPUTopology.

from laboneq_applications.qpu_types.tunable_coupler import TunableCoupler

# define desired couplings
couplings = {"c_q0q1": ("q0", "q1")}

# add signal lines for tunable couplers
for n, key in enumerate(couplings):
    # the first HDAWG channels are already occupied by the qubit flux lines
    channel_id = number_of_qubits + n
    if key in setup.logical_signal_groups:
        print(f"INFO: Logical signal for group {key} is already in setup")
    else:
        setup.add_connections(
            "hdawg_0",
            create_connection(to_signal=f"{key}/flux", ports=f"SIGOUTS/{channel_id}"),
        )

couplers = TunableCoupler.from_device_setup(setup, qubit_uids=couplings.keys())

Quantum Operations

Create the set of TunableCouplerOperations. It extends TunableTransmonOperations with the coupler-mediated two-qubit operations we will calibrate in this guide: cz, as well as iswap and discharge_coupler. These operations look up the coupler and the gate parameters from the QPU topology edge connecting the two qubits, so no further operation needs to be defined.

from laboneq_applications.qpu_types.tunable_coupler import TunableCouplerOperations

qops = TunableCouplerOperations()

QPU

Now that we have all the ingredients, let's create the QPU object from the qubits, couplers and the quantum operations.

from laboneq.dsl.quantum import QPU

qpu = QPU(qubits + couplers, quantum_operations=qops)

QPU Topology

We now define the topology of this chip following the couplings defined before. For each coupler we add, in both directions:

  • an edge tagged "coupler", describing the physical connectivity;
  • an edge tagged "cz" carrying an instance of CzParameters. This is where the cz operation and the calibration workflows below read and store the gate parameters.

We add the edges in both directions to support the fact that the coupler can act in both directions; each direction carries its own CzParameters instance, since for instance the phase corrections depend on which qubit plays the role of the control.

For the qubit-driven gate flavor calibrated in this guide, we explicitly set the control_pulse (the modulated fast-flux pulse on the qubit) and use a constant baseband pulse on the coupler:

from laboneq_applications.qpu_types.tunable_coupler import CzParameters

for coupler, (q0, q1) in couplings.items():
    for source, target in ((q0, q1), (q1, q0)):
        qpu.topology.add_edge(
            source_node=source,
            target_node=target,
            quantum_element=coupler,
            tag="coupler",
        )
        qpu.topology.add_edge(
            source_node=source,
            target_node=target,
            quantum_element=coupler,
            tag="cz",
            parameters=CzParameters(
                control_pulse={
                    "function": "modulated_flux",
                    "amplitude": 0.0,
                    "length": 100e-9,
                    "frequency": 300e6,
                },
                coupler_pulse={
                    "function": "const",
                    "amplitude": 0.0,
                    "length": 100e-9,
                },
            ),
        )

Let's take a look at it by plotting the topology!

qpu.topology.plot();

The "cz" edge now holds the qubit-driven gate parameters: the modulated_flux pulse (a Gaussian-square envelope modulated at the parametric-drive frequency) on the qubit flux line and a constant pulse on the coupler flux line:

qpu.topology["cz", "q0", "q1"].parameters

Alternatively, use the demo platform helper

The construction above is also available as a single helper function in the contrib library, which is convenient for testing and for trying out the workflows in emulation:

from laboneq_applications.contrib.qpu_types import demo_platform_coupled_transmons

platform = demo_platform_coupled_transmons(n_qubits=2)
setup = platform.setup
qpu = platform.qpu

If you already have a DeviceSetup and a QPU stored in .json files, you can simply load them back using:

from laboneq import serializers

setup = serializers.load(full_path_to_device_setup_file)
qpu = serializers.load(full_path_to_qpu_file)

Connect to Session

session = Session(setup)
session.connect(do_emulation=True)  # do_emulation=False when at a real setup

Create a FolderStore for Saving Data

The experiment Workflows can automatically save the inputs and outputs of all their tasks to the folder path we specify when instantiating the FolderStore. Here, we choose the current working directory.

# import FolderStore from the `workflow` namespace of LabOne Q, which was imported
# from `laboneq.simple`
from pathlib import Path

folder_store = workflow.logbook.FolderStore(Path.cwd())

We disable saving in this guide. To enable it, simply run folder_store.activate().

folder_store.deactivate()

Optional: Configure the LoggingStore

You can also activate/deactivate the LoggingStore, which is used for displaying the Workflow logging information in the notebook; see again the tutorial on Recording Experiment Workflow Results for details.

Displaying the Workflow logging information is activated by default, but here we deactivate it to shorten the outputs, which are not very meaningful in emulation mode.

We recommend that you do not deactivate the Workflow logging in practice.

from laboneq.workflow.logbook import LoggingStore

logging_store = LoggingStore()
logging_store.deactivate()

Step 1: Chevron

You'll now run the chevron experiment workflow to find the operating point of the CZ gate. The experiment prepares both qubits in the \(|1\rangle\) state using \(\pi\)-pulses, applies the pair of fast-flux pulses (modulated pulse on the qubit, baseband pulse on the coupler), and measures both qubits at the end of the sequence:

Pulse sequence of the chevron experiment

The workflow sweeps the duration of the fast-flux pulses (outer sweep) and the amplitude of one of the two pulses (inner sweep). The amplitude range should be chosen to bring the \(|11\rangle\) and \(|20\rangle\) states into resonance somewhere within the sweep, and the maximum duration should be large enough to observe at least one full population swap in the \(|11\rangle\)–\(|20\rangle\) subspace. The pulse whose amplitude is swept is the one that drives the gate, so it follows the flavor of the edge: the qubit pulse (control_pulse) for the qubit-driven flavor used here, and the coupler pulse (coupler_pulse) on an edge that leaves control_pulse unset.

The measured qubit population forms the characteristic chevron pattern sketched below (simulation). From sinusoidal fits to horizontal slices of the data, one can determine the pulse amplitude \(a_{CZ}\) with the smallest oscillation frequency — the point where \(|11\rangle\) and \(|20\rangle\) are exactly on resonance — and the duration \(l_{CZ}\) at which the population has made its first full round-trip back into \(|11\rangle\) for \(a = a_{CZ}\). This point \((a_{CZ}, l_{CZ})\), marked with a diamond below, is the operating point of the gate:

Simulated chevron pattern

The current automated analysis uses a simpler and more robust criterion suitable as a starting point: it extracts the sweep point of maximum interaction (maximum population transfer on the target qubit). With update(True), this (duration, amplitude) point is written into the "cz" edge, providing the starting point for the finer calibrations below. The duration goes to coupler_pulse, since that is where the cz operation reads the gate length from, and the amplitude to the pulse that drives the gate.

import numpy as np

from laboneq_applications.contrib.experiments.two_qubit import chevron

options = chevron.experiment_workflow.options()
options.count(1024)
options.do_analysis(True)
options.update(True)

qubit_pairs = [["q0", "q1"]]

chevron_result = chevron.experiment_workflow(
    session=session,
    qpu=qpu,
    qubit_pairs=qubit_pairs,
    durations=[np.linspace(0.1e-6, 1.0e-6, 11) for _ in qubit_pairs],
    amplitudes=[np.linspace(0.1, 0.6, 11) for _ in qubit_pairs],
    options=options,
).run()

Let's inspect the pulse sequence of the experiment using plot_simulation and the output simulator:

from laboneq.contrib.example_helpers.plotting.plot_helpers import plot_simulation

compiled_experiment = chevron_result.tasks["compile_experiment"].output
plot_simulation(compiled_experiment, start_time=0, length=10e-6)

The analysis workflow returns the old and new edge parameters. The entries are keyed by the edge signatures "tag:source_node_uid:target_node_uid"; the update_qpu_edges task converts these to the edge keys accepted by qpu.update. Since we ran with update(True), the pulse parameters of the "cz" edge have already been updated:

analysis_output = chevron_result.tasks["analysis_workflow"].output
print(analysis_output["new_parameter_values"])
edge_parameters = qpu.topology["cz", "q0", "q1"].parameters
print(edge_parameters.coupler_pulse)
print(edge_parameters.control_pulse)

Note that in emulation mode the measured data is random, so the extracted operating point is meaningless here — on real hardware you would see the chevron pattern in the population plots produced by the analysis.

Step 2: JAZZ — conditional-phase calibration

Next, fine-tune the conditional phase of the gate. Conceptually, a conditional-phase measurement consists of two Ramsey-type experiments on one of the qubits, with the other qubit prepared once in \(|0\rangle\) and once in \(|1\rangle\). In each Ramsey experiment, the phase \(\varphi\) of the second \(\pi/2\)-pulse is swept, and a sinusoidal fit to the population oscillation yields a phase \(\delta_i\). The difference \(\delta_1 - \delta_2\) between the two experiments is the conditional phase of the gate, with a target value of \(\pi\).

The JAZZ sequence used here is an echo variant of this measurement: two CZ gates, each of half the duration, enclose an echo \(\pi\)-pulse on both qubits. The echo makes the sequence insensitive to the single-qubit dynamical phases and to low-frequency dephasing, so that the fitted oscillation directly reflects the conditional-phase accumulation:

Pulse sequence of the JAZZ experiment

The analysis fits the oscillation of the control-qubit population versus the flux-pulse amplitude and extracts the amplitude at which the gate accumulates a conditional phase of \(\pi\). With update(True), this amplitude is written into the pulse that drives the gate and the corresponding duration into the coupler_pulse of the edge. Here we keep the update disabled since the emulated data is random.

On real hardware, a robust procedure is to iterate [1]:

  1. Measure the conditional phase for 10–20 values of the pulse amplitude \(a\) centered around \(a_{CZ}\), at fixed duration \(l \approx l_{CZ}\), and set the amplitude that yields a conditional phase of \(\pi\).
  2. Measure the conditional phase and the leakage for 10–20 values of the pulse duration \(l\) centered around \(l_{CZ}\) (the conditional phase is expected to vary only little), and choose the duration that minimizes leakage. Leakage can be monitored by also reading out the qubit that passes through the \(|2\rangle\) state during the gate.
  3. Repeat step 1.
from laboneq_applications.contrib.experiments.two_qubit import jazz

options = jazz.experiment_workflow.options()
options.count(1024)
options.do_analysis(True)

jazz_result = jazz.experiment_workflow(
    session=session,
    qpu=qpu,
    qubit_pairs=qubit_pairs,
    durations=[np.linspace(0.1e-6, 1.0e-6, 11) for _ in qubit_pairs],
    amplitudes=[np.linspace(0.1, 0.6, 11) for _ in qubit_pairs],
    options=options,
).run()

Step 3: Single-qubit phase corrections

Finally, determine the single-qubit phase corrections. During the flux pulses, each qubit accumulates a dynamical phase (for instance from the ac-Stark shift of the parametric drive), which must be compensated so that the gate acts as a pure CZ in the computational frame. The compensation is applied as a virtual-Z rotation — precisely the rz operations the cz quantum operation plays at the end, with the angles taken from the "cz" edge parameters.

The measurement is again Ramsey-type: a \(\pi/2\)-pulse, the CZ gate, and a second \(\pi/2\)-pulse with swept phase, run once for the control and once for the target qubit (with the respective other qubit left in \(|0\rangle\), so that no conditional phase contributes):

Pulse sequence of the single-qubit phase-correction experiment

The analysis fits a cosine to both oscillations and extracts the phase offsets. With update(True), these are written into the control_angle and target_angle parameters of the "cz" edge, and the cz operation will apply them automatically from then on.

from laboneq_applications.contrib.experiments.two_qubit import phase_correction

options = phase_correction.experiment_workflow.options()
options.count(1024)
options.do_analysis(True)

phase_result = phase_correction.experiment_workflow(
    session=session,
    qpu=qpu,
    qubit_pairs=qubit_pairs,
    phases=[np.linspace(0, 2 * np.pi, 21) for _ in qubit_pairs],
    options=options,
).run()
phase_analysis = phase_result.tasks["analysis_workflow"].output
phase_analysis["new_parameter_values"]

Wrapping up

The "cz" edge now holds the full set of gate parameters:

qpu.topology["cz", "q0", "q1"].parameters

After these three steps on real hardware, the calibrated gate can be played simply as:

qop = qpu.quantum_operations
qop.cz(qpu["q0"], qpu["q1"])

To assess the fidelity of the calibrated gate, continue with the two-qubit interleaved randomized benchmarking workflow, laboneq_applications.contrib.experiments.two_qubit.two_qubit_irb.

References

[1] M. A. Rol et al., Fast, High-Fidelity Conditional-Phase Gate Exploiting Leakage Interference in Weakly Anharmonic Superconducting Qubits, Phys. Rev. Lett. 123, 120502 (2019), arXiv:1903.02492.

[2] S. Krinner et al., Realizing repeated quantum error correction in a distance-three surface code, Nature 605, 669 (2022).

[3] N. Lacroix et al., Improving the Performance of Deep Quantum Optimization Algorithms with Continuous Gate Sets, PRX Quantum 1, 020304 (2020), arXiv:2005.05275.